Femur Fracture Fixation (Stryker® Gamma Nail)


due to its heavy consumption, if the femur is fractured and needs surgery for haunt, the fracture fixation needs to be heavy-duty. This brings in the use of the Stryker® gamma nail, which is used for repairing femur fractures that help the bone bring around by rights. When a person fractures their femur, sometimes it occurs near the lead of the femur by the hep. If broken at the upper end, this can cause hip issues and cause the affected role to become ineffective to walk. The Stryker® da gamma pinpoint helps patients recover more promptly and have better long-run mend .

coarse Causes of Femur Fracture

A femur fracture that occurs at the upper berth end of the femur is uncommon because it is broadly caused by extreme forcible injury. This normally means a motor vehicle accident or a fall from a great height. Most of these breaks are accompanied by other serious injuries like hip dislocation and therefore this surgery can help the patient ’ s recovery greatly. other causes of femoral fractures include bone weakness. This could happen in a young person with a discipline like cerebral palsy or brawny muscular dystrophy. This can besides occur in aged patients with osteoporosis or other cram problems who might fall and break their femur. Falls are common ways to injure the femur, because the point of the femur is the first thing person lands on if they land on their side .

Basics of Femur Fracture Fixation Using a Stryker® Gamma Nail

This operation is moderately incursive and repairs and strengthens the fracture femur bone. There are three steps involved once the patient has been placed under anesthetic and prepped for the surgery.

beginning incision : placement of the Nail

The foremost incision of the surgery is made near the top of the femur to reveal the fracture area. This is the largest incision made during the operating room. The surgeon realigns the fracture bones and drills a trap from the top of the femur into the femoral shaft. This first hole is where the Stryker® gamma nail down is inserted. The nail is hollow inside and has two other openings on the sides. The adjacent incisions will be made to wrinkle up with these other openings.

second incision : stabilizing

once the Stryker® da gamma nail has been placed where the surgeon wants, the second gear incision is made. This incision lines up with a hole that is about one third of the way down the nail. The surgeon drills a hole through the bone, through the hole in the Stryker® da gamma nail, up into the ball dowry of the femur. This is the separate of the femur that connects to the pelvis, in a ball and socket type joint. The hole is then filled by another stabilize gat. This is screwed into place through the nail, creating a skew “ metric ton ” shape that follows the form of the femur. Another small cheat is placed and secures the rod inside the hollow main nail down .

third base incision : distal Screw

A small third base incision is created at the very bottom of the Stryker® gamma nail. This little incision reveals a place where the nail has a hole vertical to the very bottom. A modest hole is drilled in the femur to reveal the hole in the locate nail. A minor screw is then inserted to keep the collar from being pulled out of the femur from the top. then, a cap is placed on the head of the Stryker® gamma nail, to seal the entire thing together .

convalescence After Femur Fracture Fixation

once the surgery has been completed, the patient is able to return home plate after a few days in the hospital. This does depend on any other injuries they may have sustained from the initial accident that caused the fault. After a few weeks, a follow up date is made to make indisputable the hardware has not moved and that the femur is growing back in concert. Most patients take respective months to be able to regain normal use of their leg. Most doctors prescribe physical therapy to help the affected role find mobility deoxyadenosine monophosphate quickly as possible .